Get your free estimateHVAC Before & After in Atlanta, GA
Talk is cheap in this trade. Anyone can promise a quiet system or a cool upstairs. What actually matters is what changed between the first visit and the final walkthrough. On this page, we show the work itself: the equipment we replaced, the problems we found, and what the system looked like when we left. We’re still loading photos from the field, so most of these frames are placeholders for now. As our techs document each job, the gallery fills in. Check back to see real Atlanta homes the way our customers did: before, during, and after.
Styles & brands we work with






Recent Transformations
AC Repair: Failed Compressor in a 2009 Goodman Condenser

The homeowner called at 6:50 a.m. on a Tuesday. The system had been running nonstop since Sunday night and the house was still 84 degrees. Our tech found the compressor grounded, not a capacitor or contactor issue. A compressor swap on a 16-year-old Goodman made no sense financially, so we presented a written price for a full condenser replacement that morning. By 4:00 p.m., the new unit was running and the house dropped to 72 in under three hours. The old unit photo will be posted alongside the new Carrier unit as soon as we pull it from the job file.

Furnace Repair: Cracked Heat Exchanger in a Trane XV80

This one could have ended badly. The homeowner called for a standard tune-up, and our tech caught a cracked heat exchanger with a combustion analyzer reading that raised the carbon monoxide concern immediately. We shut the gas off at the unit and walked the customer through the finding, showing them the crack with an inspection camera. The furnace was 14 years old, and the heat exchanger was under a parts warranty, but the labor to swap it would have been more than half the cost of a new furnace. The customer chose furnace replacement. We quoted it that afternoon, installed it two days later, and left the crawlspace cleaner than we found it.

AC Maintenance: Clogged Indoor Coil on a Rheem, Buckhead

This one’s a good reminder that maintenance catches problems before they become breakdowns. The homeowners said the system was “working fine, just not as cold as last year.” The coil was so loaded that the system was moving about 60% of the airflow it should, and the compressor was running hot. We pulled the coil, chemically cleaned it, cleared the drain line, and replaced the media filter. Final static pressure: 0.45″ WC. Supply air temp mid-vent went from 61°F to 52°F. The customer said it felt like a new air conditioner.

AC Repair: Refrigerant Leak at a Braze Joint, Lennox System

Slow leaks are the most annoying ones. The system would cool fine for a week, then gradually lose capacity until the customer called us again. Two prior companies recharged it and left. We don’t do that. Our tech isolated the leak with an electronic sniffer, confirmed with a nitrogen pressure test, and found the suspect joint at the air handler. We repaired the braze joint, pulled a deep vacuum to below 500 microns, and weighed in a factory-spec charge. The invoice listed both the before and after pressures and temperatures. The repair is covered by our 365-Day Done Right Promise, and the system has held its charge through the rest of the summer.

Furnace Repair: Failed Inducer Motor on a Carrier Infinity, Atlanta Winter

I don’t like telling customers their furnace died on the coldest night of the year, but that’s how it goes. The call came in at 9:15 p.m. A live person answered, as always. Our tech arrived at 10:20 and confirmed the inducer had seized. We had the part on the truck, which doesn’t always happen but saves the night when it does. Replaced the motor, cleared the fault codes, and got the house back to 70 by midnight. This job is a good example of why we carry common failure parts instead of making every repair a two-visit ordeal. Written price before starting, written guarantee covering the part and labor for 365 days.

AC Maintenance: Condenser Coil Restoration on a 2014 Lennox, Decatur

High head pressure is just the compressor working harder than it should, and it’s a direct path to a shorter compressor life. We pulled the top, split the coil if needed, and used a coil-safe cleaning solution and low-pressure rinse. The after photo will show a coil you can see through. Head pressure after clean: 330 PSIG, right where the manufacturer wants it for the outdoor temp that day. The customer also got a written report showing the before and after readings, not just a “looks clean now” note.

Want Results Like These?
Every job gets a written price before any work starts, and every repair includes a 365-day guarantee. If it’s not done right, we return and fix it at no charge. That’s the whole deal. Call (762) 465-4570 to schedule service in Atlanta. A real person answers, 24 hours a day.
Written by Devin Marlowe, Owner at Brandt HVAC Co Atlanta, serving Atlanta since 2003.